Vue de la page 45
Agilent Technologies, Inc.
Agilent Technologies, Inc. 46 SATA PHY, TSG & OOB Test MOI v.1.1 Revision 1.4
Example Typical products behavior for in specification COMINIT/COMRESET sequence at 210mV
In this figure, the products correctly responds to a valid in-spec COMRESET/COMWAKE OOB
initialization sequence at 210mV, thus passing the threshold test. The other requirement for passing is to
successfully REJECT the same HOST OOB signal sent at 40mV (for Gen 1i) or 60mV (for Gen 2i).